57 AIEW Member Electrical Product Catalogue Issue 20 Surge Protection Devices www.surgedevices.co.uk SY12350KA4P Type 1+2+3 Combined Lightning & Surge Arrester fully compliant to BSEN61643-11, BSEN62305 & BS7671 To be used on the main incoming panel of an installation where the building has an external lightning protection system in place or is being fed by over head power lines. • Suitable for all types of installations (TNC-S, TN-S, PME & TT) • Three phase and Neutral device • Pluggable, replacement modules • Remote changeover contact • DIN rail mountable • 50kA 10/30µs • Backup fuse / MCB 63A SY12325KA2P Type 1+2+3 Combined Lightning & Surge Arrester fully compliant to BSEN61643-11, BSEN62305 & BS7671 To be used on the main incoming panel of an installation where the building has an external lightning protection system in place or is being fed by over head power lines • Suitable for all types of installations (TNC-S, TN-S, PME & TT) • Single phase and Neutral device. • Pluggable, replacement modules • Remote changeover contact • DIN rail mountable • 25kA 10/30µs • Backup fuse / MCB 63A SY2-D Type 2 Surge Arrester, fully compliant to BSEN61643-11, BSEN62305 & BS7671 Domestic This device is mainly used in domestic installations. It can also be used in larger installations to protect final circuits as it easily fits into a consumer unit. • Suitable for all types of installations (TNC-S, TN-S, PME & TT) • Single phase and neutral device • Pluggable, replacement modules • DIN rail mountable • 15kA 8/20µs • Backup fuse / MCB 16-32A SY1-C40XLED Type 2 Surge Arrester, fully compliant to BSEN61643-11, BSEN62305 & BS7671 Commercial / Industrial To be used on the main incoming panel of an installation where the building does not have an external lightning protection system and is not being fed by over head power lines. This device is also used on any sub-distribution boards more that 10 metres away from the main incoming panel. • Suitable for all types of installations (TNC-S, TN-S, PME & TT) • Single phase and neutral device • Pluggable, replacement modules • Remote changeover contact • DIN rail mountable • 40kA 8/20µs • Backup fuse / MCB 16-32A SY2-C40XLED Type 2 Surge Arrester, fully compliant to BSEN61643-11, BSEN62305 & BS7671 Commercial / Industrial To be used on the main incoming panel of an installation where the building does not have an external lightning protection system and is not being fed by over head power lines. This device is also used on any sub-distribution boards more that 10 metres away from the main incoming panel. • Suitable for all types of installations (TNC-S, TN-S, PME & TT) • Three phase and neutral device • Pluggable, replacement modules • Remote changeover contact • DIN rail mountable • 40kA 8/20µs • Backup fuse / MCB 16-32A Surge Protection Devices Type 2 Surge Protection Devices Type 1, 2 & 3

RkJQdWJsaXNoZXIy MjQwMjM=